TH343X / TH344X Series
Wideband Multi-Channel Digital Power Meter, DC / 0.1 Hz – 100 kHz
A wideband digital power meter for voltage/current RMS, active/reactive/ apparent power, power factor, harmonics, energy integration and waveform/vector display, covering DC and 0.1 Hz – 100 kHz, well beyond mains frequency, for switching power supplies, inverters, motor drives and other non-sinusoidal or high-frequency signals. Six models combine two current tiers (2 A / 20 A) with 1, 3 or 4-channel configurations.
Technical question about this series? Ask our team.
Key features
- 0.1% basic accuracy (reading + range) on voltage and current, across all six models
- Wide input bandwidth DC / 0.1 Hz – 100 kHz for switching supplies, inverters, motor drives and other wideband signals
- 1 / 3 / 4-channel combinations across six models (TH3431 – TH3444)
- 7" (800 × 480) colour TFT resistive touch screen, mouse operation supported
- 3/4-channel models: 5 wiring modes (1P2W / 1P3W / 3P3W / 3P4W / 3V3A); 1-channel models: 1P2W
- Harmonic analysis to 1.2 kHz, list and bar-graph display; waveform and vector display
- 8-channel programmable comparator output via HANDLER interface
- Selectable measurement update rate: 0.1 / 0.25 / 0.5 / 1 / 2 / 10 / 20 s
- USB Host, USB Device, LAN, RS232 standard; RS485 as a factory-installed option
- SCPI command set and MODBUS protocol
6 models, one platform
| Model | Channels | Current range | Power range | Micro current | Quote |
|---|---|---|---|---|---|
| TH3431 | 1 | 0.01 mA – 2 A | 0.01 mW – 1.2 kW | Yes | Quote |
| TH3433 | 3 | 0.01 mA – 2 A | 0.01 mW – 1.2 kW | Yes | Quote |
| TH3434 | 4 | 0.01 mA – 2 A | 0.01 mW – 1.2 kW | Yes | Quote |
| TH3441 | 1 | 0.1 mA – 20 A | 0.1 mW – 12 kW | No | Quote |
| TH3443 | 3 | 0.1 mA – 20 A | 0.1 mW – 12 kW | No | Quote |
| TH3444 | 4 | 0.1 mA – 20 A | 0.1 mW – 12 kW | No | Quote |
All six models share the same voltage range (1 V – 600 V), 0.1% basic accuracy, DC / 0.1 Hz – 100 kHz bandwidth and chassis. TH343X (2 A tier) adds micro-current measurement; TH344X (20 A tier) covers higher-current loads.
Applications
Source equipment
AC and DC power supplies, linear and switching power supplies, inverters and other source-output equipment.
Load equipment
Household and industrial appliances, electronic loads and other power-consuming equipment.
Industry applications
Motors and transformers, electronic production lines, lighting, aerospace/military, network communication, audio/video and monitoring equipment.
Technical specifications
| Parameter | TH343X (2 A): TH3431 / TH3433 / TH3434 | TH344X (20 A): TH3441 / TH3443 / TH3444 |
|---|---|---|
| Display | 7" (800 × 480) colour TFT resistive touch screen | |
| Wiring modes | 1-channel models: 1P2W only · 3/4-channel models: 1P2W · 1P3W · 3P3W · 3P4W · 3V3A | |
| Basic features | AC, DC, precision type, harmonic analysis, electric energy test | |
| Display modes | Data, integration data, waveform graph, vector analysis, histogram | |
| Basic accuracy (1 year) | Voltage: 0.1% reading + 0.1% range · Current: ±(0.1% reading + 0.1% range) | |
| Voltage range | 1 V – 600 V (15 / 30 / 60 / 150 / 300 / 600 V) | |
| Voltage resolution / input impedance | 0.001 V / 2 MΩ | |
| Voltage max. input | 1000 V (1 s) / 700 V (continuous) | |
| Current range | 0.01 mA – 2 A: 0.5/1/2/5/10/20 mA (4 Ω); 0.05/0.1/0.2/0.5/1/2 A (40 mΩ) | 0.1 mA – 20 A: 5/10/20/50/100/200 mA (400 mΩ); 0.5/1/2/5/10/20 A (4 mΩ) |
| Current resolution | 0.1 µA | 1 µA |
| Current max. input | 3 A (1 s) / 2 A (continuous) | 30 A (1 s) / 20 A (continuous) |
| Micro current | Yes | No |
| Power range | 0.01 mW – 1.2 kW | 0.1 mW – 12 kW |
| Power resolution | 0.001 mW | 0.01 mW |
| Frequency range | DC / 0.1 Hz – 100 kHz, 500 Hz filter; resolution 0.01 Hz | |
| Power factor | −1.000 – 1.000, resolution 0.001 | |
| Harmonic analysis | 10 Hz – 1.2 kHz, accuracy ±(5% reading + 0.3% range) | |
| Energy integration | 0 – 99999 kWh, resolution 0.001 Wh, accuracy ±(0.2% RDG + 0.3% RNG) | |
| Energy timing | 0 – 9999:59:59, resolution 1 s, accuracy ±0.05% | |
| Update rate | 0.1 / 0.25 / 0.5 / 1 / 2 / 10 / 20 s, selectable | |
| Range / lock | Auto / manual range; data lock; keyboard/touch-screen lock | |
| Comparator | Over-limit sound and light alarm, 8-channel programmable relay output (HANDLER) | |
| Data storage | Test results to USB disk for PC-side analysis; waveform data and setting files; settings save and load | |
| Power supply | AC 220 V ±10%, 50/60 Hz ±5%, soft power switch | |
| Working / shelf size | 236 × 154 × 475.5 mm (with sleeve) / 215 × 132 × 441 mm | |
| Weight | 8.1 kg | |
Source: TH343X / TH344X Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- USB Hoststandard (FAT16/32)
- USB Devicestandard (USBTMC or CDC)
- LANstandard
- Handlerstandard
- SCPI / MODBUSstandard
- RS232standard
- RS485factory option in place of RS232
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
For mains-frequency testing (DC / 45–420 Hz) see the TH342X Series.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH343X / TH344X Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.