TH2886S Series
10-Channel Impulse Winding Tester, up to 6000 V
A non-destructive high-voltage impulse tester for wound components such as motor coils, transformer windings and wound inductors. TH2886S applies matched impulse pulses to the device under test and a stored reference winding, then compares the transient decay waveforms to reveal turn-to-turn and layer-to-layer insulation faults, shorted turns and winding-count deviations. With 10 test channels and up to 1.098 J of impulse energy, it is built for multi-coil production testing.
Technical question about this series? Ask our team.
Key features
- 10 test channels for multi-coil production-line testing
- Impulse voltage 50–6000 V, 2 V step, accuracy ±[5% of setting] ±2 V
- Max. impulse energy 1.098 J, for testing coils with damaged or breached wire insulation
- Waveform acquisition up to 200 Msps, 12-bit resolution, 12k storage depth, 1–32-shot averaging
- Inductance test range ≥ 10 µH; 1–32 test pulses, 0–9 excitation pulses per step
- Nine comparison methods: area, zone, flutter, Laplace, peak ratio, peak ratio difference, angular frequency, damping coefficient, quality factor
- Patented angular-frequency / damping-coefficient comparison algorithm (CN117192443)
- 10.1" capacitive touchscreen, 1280 × 800, English UI
- PASS/FAIL judgement with LED indicators and buzzer; built-in measurement statistics
- RS232C, USB Host, USB Device, Gigabit LAN and Handler standard; GPIB optional
Model
TH2886S
- Test channels
- 10
- Impulse voltage
- 50 – 6000 V
- Max. impulse energy
- 1.098 J
- Sample rate
- 200 Msps
Applications
Motor coils
Turn-to-turn insulation and interlayer short-circuit testing of motor windings.
Transformer coils
Turn-to-turn insulation and interlayer short-circuit testing of transformer windings.
Wound inductors
Turn-to-turn insulation and interlayer short-circuit testing of wound inductor coils.
Technical specifications
| Parameter | TH2886S |
|---|---|
| Impulse voltage | 50 – 6000 V, 2 V step |
| Voltage accuracy | ±[5% of setting] ±2 V |
| Test channels | 10 |
| Inductance test range | ≥ 10 µH |
| Applied pulses | Test pulse 1–32; excitation pulse 0–9 |
| Impulse energy | 1.098 J (max.) |
| Measurement speed | 120 ms per test |
| Waveform acquisition | Sample rate up to 200 Msps (8 steps adjustable); 12 bits; storage depth 12k; averaging 1–32 |
| Comparison methods | Area, zone (area difference), flutter (burr total, 1st derivative), Laplace (max burr, 2nd derivative), peak ratio, peak ratio difference, angular frequency, damping coefficient, quality factor |
| Waveform measurement | Voltage, frequency, time |
| Trigger mode | Manual, external, bus |
| Judgement output | PASS/FAIL display, LED indicators, buzzer alarm |
| Measurement statistics | Built-in |
| Display | 10.1" capacitive touchscreen, 1280 × 800, English UI |
| Data storage | Internal 32 GB; USB-expandable |
| Power supply | 100 – 240 V AC, 47.5 – 63 Hz, ≤ 200 VA |
| Warm-up time | ≥ 15 minutes |
| Operating environment | 0 °C to 40 °C, humidity ≤ 75% R.H. |
| Safety and EMC | IEC 61010-1:2001, IEC 61326-2-1:2005 |
| Dimensions (W × H × D) | 430 × 177 × 570 mm |
| Weight | approx. 27 kg |
Source: TH2886S Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232Cstandard
- USB Hoststandard
- USB Devicestandard
- LANstandard, 1 Gbps
- Handlerstandard
- SCPIstandard
- GPIBoptional
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
| TH90017A | High-voltage test cable (High / Low test leads) |
Optional test fixtures and custom configurations are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH2886S Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.