Hipot & Insulation Resistance Testers

TH9130S Series

Multi-Channel High-Power Withstand-Voltage & Ground-Bond Tester

A multi-channel derivative of the TH9130 platform, built for production-line safety testing where several DUTs or test points are scanned in sequence. Combines AC/DC withstand voltage, insulation resistance, ground bond and continuity testing with user-selectable 4- or 8-channel rear-panel scanning modules and hardware contact check (CK) for reliable multi-point testing.

TH9130STH9131S CE

Technical question about this series? Ask our team.

Key features

  • 7-inch capacitive touchscreen, 800 × 480, English UI
  • Five-in-one: ACW, DCW, insulation resistance, ground bond and continuity, with multi-channel scanning
  • 500 VA AC withstand-voltage output (TH9130S); insulation resistance test up to 6 kV / 50 GΩ
  • Ground bond test up to 40 A; can run simultaneously with withstand voltage
  • Hardware contact check (CK) confirms probe contact before applying high voltage
  • Rear-panel scanning module: 4 or 8 HV channels, 4 or 8 ground-bond channels (2-wire or 4-wire)
  • Open/short-circuit detection (OSC) and arc detection (ARC)
  • Single-screen step view plus list mode with all step results and pass/fail
  • Shock-protection cut-off, lockable panel, pass/fail alarm
  • Standard SCPI; storage for 100 files, 50 steps per file

2 models, one platform

TH9130S

AC withstand
5.0 kV / 100 mA / 500 VA
DC withstand
6.0 kV / 20 mA / 120 VA
Synchronous ACW + GB
5 kVac/30 mAac & 30 Aac/150 mΩ
Weight
40 kg
Request a quote for TH9130S

TH9131S

AC withstand
5.0 kV / 40 mA / 200 VA
DC withstand
6.0 kV / 20 mA / 120 VA
Synchronous ACW + GB
5 kVac/30 mAac & 30 Aac/150 mΩ
Weight
38 kg
Request a quote for TH9131S

A rear-panel scanning module must be selected when ordering; the base instrument does not ship without one. The module is common to TH9130S and TH9131S.

Scanning module options

Feature-004-001-002-003
HV channels (ACW / DCW / IR)488—
Hardware contact check (CK)✓✓✓—
Ground-bond (GB) channels48—8
GB wiringFour-wireTwo-wire—Four-wire
Continuity✓✓✓✓

Module -004 offers fewer channels with four-wire (Kelvin) ground-bond wiring; module -001 maximises channel count with two-wire ground bond; module -002 is high-voltage scanning only; module -003 is ground-bond scanning only (no high-voltage channels, no CK).

Applications

Household appliances and lighting

Electrical safety testing on the production line; comprehensive lighting-appliance safety testing.

Motors and high-power equipment

Comprehensive electric-motor safety testing; withstand-voltage and ground-bond testing of high-power appliances.

Electronic components

Multi-point production-line component safety testing.

Technical specifications

ParameterTH9130STH9131S
AC voltage range 0.05 – 5.0 kV, 50/60 Hz ±0.1% sine wave
AC output power 500 VA (5.0 kV / 100 mA)200 VA (5.0 kV / 40 mA)
DC voltage range 0.05 – 6.0 kV
DC output power 120 VA (6.0 kV / 20 mA)
Voltage accuracy ±(1% set value + 5 V); resolution 2 V
AC current range 0.001 – 120 mA (V ≤ 4 kV) / 100 mA (V > 4 kV)0.001 – 40 mA
DC current range 0.0001 – 20 mA
Test / rise / fall / wait time 0.3–999 s / 0.1–999 s / 0.1–999 s / 0.1–999 s (0 = continuous / off)
Arc detection (AC / DC) 1.0–20.0 mA / 1.0–10.0 mA1.0–20.0 mA / —
Max. short-circuit current (AC) 200 mA80 mA
IR output voltage DC 0.05 – 6.0 kV, resolution 2 V, accuracy ±(1% reading + 5 V)
IR resistance range 0.05 MΩ – 50.0 GΩ
IR accuracy (V ≥ 500 V) 1 MΩ–1 GΩ: ±(3% reading + 1 MΩ); 1–10 GΩ: ±(7% reading + 0.2 GΩ); 10–50 GΩ: ±(10% reading + 0.5 GΩ)
IR accuracy (V < 500 V) 1 MΩ – 1 GΩ: ±(5% reading + 100 V/Vs × 10 MΩ)
Ground bond output current 1.00 – 40.00 A, ±(2% set value + 2 digits)
Ground bond test voltage 3.00 – 8.00 V, 50/60 Hz ±0.1%
Ground bond resistance range 0–600 mΩ (1–10 A), 0–200 mΩ (10–30 A), 0–150 mΩ (30–40 A); accuracy ±(2–3% reading + 2–3 digits)
Synchronous ACW + GB test 5 kVac/30 mAac & 30 Aac/150 mΩ
Continuity 0.0001–0.1 A / 0.00–10,000 Ω; accuracy ±(1% reading + 3–10 digits)
OSC detection 0.001–40 nF; open 10–100%, short 100–500%
HV channels 4 (module -004) or 8 (modules -001 / -002); none on module -003
Ground-bond channels 4 (module -004, four-wire), 8 (module -001, two-wire), 8 (module -003, four-wire); none on module -002
Contact check (CK) Standard on modules -004 / -001 / -002; not available on module -003
Shock protection 0.5 mA ±0.25 mA, selectable on/off; interlock pin must be pulled low to enable HV output
Alarm / lock Pass: short tone + green light. Fail: long tone + red light. Lock-on-fail, panel key-lock
Storage 100 files, 50 steps per file
Operating / storage environment 0–45 °C, 20–90% RH / −10–55 °C, < 80% RH
Power supply / power 100–240 V AC, 47–63 Hz; no-load < 100 W, rated 1200 W
Dimensions (W × H × D) 430 × 132 × 550 mm
Weight 40 kg (all modules)38 kg (all modules)

Source: TH9130S / TH9131S Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard
  • USB Devicestandard
  • LANstandard
  • Handlerstandard
  • SCPIstandard
  • GPIBoptional

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH90003RWithstand-voltage test lead
TH26035BHigh-current test cable
HNB5.5-6Ring lug test lead (not with module -002)
HNB1.25-5Ring lug test lead (not with modules -001 / -002)
TH90017ATest cable (not with module -003)

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH9130S Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote