Ground Bond Testers

TH9410A / TH9411A Series

Programmable AC Ground Bond Tester, up to 45 A

A programmable AC ground bond (protective-earth continuity) tester for verifying the grounding resistance of appliances, transformers, motors and electrical equipment during safety compliance testing. An internal power-amplifier circuit drives the current output independently of supply voltage and load, and a four-terminal (Kelvin) test connection keeps the resistance reading accurate.

TH9410ATH9411A CE

Technical question about this series? Ask our team.

Key features

  • Up to 45 A (TH9410A) / 32 A (TH9411A) AC current output
  • Four-terminal (Kelvin) test mode for accurate contact-resistance measurement
  • Internal power-amplifier current drive, unaffected by supply voltage or load
  • 480 × 272-dot TFT-LCD display with English UI
  • Test time up to 999.9 s
  • Front- and rear-panel test output terminals for integration into test chassis
  • Keyboard-lock and safety interlock functions
  • Stores 20 test files, each with up to 20 test steps
  • Standard RS232, USB Host, USB Device and Handler interfaces; SCPI command set

2 models, one platform

TH9410A

Higher current, up to 45 A

Current range
1.00 – 45.00 A
Sub-ranges
1–5 / 5.01–30 / 30.01–45 A
Output voltage
8 V / 6 V
Power consumption
≤ 900 VA
Request a quote for TH9410A

TH9411A

Compact power budget, up to 32 A

Current range
1.00 – 32.00 A
Sub-ranges
1–5 / 5.01–32 A
Output voltage
8 V max
Power consumption
≤ 800 VA
Request a quote for TH9411A

Both models share the same resistance test range (0–600 mΩ), accuracy class, test-time settings and interface set; only maximum current, output-voltage compliance and power consumption differ.

Applications

Industrial and production

Automated test systems, transformers and motors, general electrical equipment.

Consumer and lighting

Household appliances, electric heating appliances, lighting products.

Specialized sectors

New energy vehicles, electronic components, medical equipment.

Technical specifications

ParameterTH9410ATH9411A
Test mode Four-terminal (Kelvin) contact-resistance test
Current range 1.00 – 45.00 A1.00 – 32.00 A
Sub-ranges 1.00–5.00 / 5.01–30.00 / 30.01–45.00 A1.00–5.00 / 5.01–32.00 A
Current accuracy ±(2% reading + 3 digits)
Current setting / readback resolution 0.01 A
Output voltage (compliance) 8 V max (1.00–5.00 A) / 6 V max (5.01–45.00 A)8 V max (full range)
Test frequency 50 / 60 Hz, ±0.1% of setting
Resistance test range 0 – 600 mΩ (Rmax ≤ 6 V / Iset; max. 600 mΩ when Iset < 10 A)
Resistance accuracy ±(2% reading + 2 digits)
Resistance resolution 1 mΩ (1.00–5.00 A) / 0.1 mΩ (5.01–45.00 A)1 mΩ (1.00–5.00 A) / 0.1 mΩ (5.01–32.00 A)
Resistance upper / lower limit 0 – 600 mΩ, 1 mΩ resolution (lower limit can be OFF)
Offset (zero) compensation 0–100 mΩ, 0.1 mΩ resolution, accuracy ±(2% setting + 2 digits)
Test time 0, 0.5 – 999.9 s (0 = continuous), 0.1 s resolution, accuracy ±(0.1% + 0.05 s)
Duty cycle (ambient ≤ 40 °C) > 40 A: 5 min max., > 30 A: 15 min max., each followed by equal rest time; < 10 A: continuous
Display 480 × 272-dot TFT-LCD, English UI
Test file storage 20 internal test files, each with up to 20 test steps
Input voltage / frequency 110 V / 220 V AC switchable; 47.5 – 63 Hz
Power consumption ≤ 900 VA≤ 800 VA
Dimensions (W × H × D) 280 × 88 × 420 mm
Net weight approx. 15 kg

Source: TH9410A / TH9411A Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard (front panel)
  • USB Devicestandard
  • Handlerstandard (START/STOP/INTERLOCK in; TEST/PASS/FAIL relay out)
  • SCPIstandard

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH26035BTwo-end test clip (1 pair)

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH9410A / TH9411A Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote