Low-Current & Insulation Resistance
TH2690 Series
Femtoammeters, Picoammeters, Electrometers and High-Resistance Meters
Eight models built around a common 6½-digit measurement platform, for the weak-current and high-resistance measurements that general-purpose digital multimeters cannot reach. The electrometer / high-resistance family (TH2690, TH2690A, TH2690H, TH2695, TH2695A) resolves current down to 0.01 fA and measures resistance up to 3 EΩ (10¹⁸ Ω) using a built-in voltage source of up to ±3000 V. The compact TH2691 / TH2691A / TH2691H family offers the same femtoamp-level ammeter core for current-only applications at lower cost.
Technical question about this series? Ask our team.
Key features
- Current resolution down to 0.01 fA (10⁻¹⁷ A)
- Resistance measurement up to 3 EΩ (10¹⁸ Ω) via built-in ±3000 / ±1500 / ±1000 V source
- 5.0" capacitive touch colour LCD, 6½-digit measurement resolution
- Four measurement modes: high-resistance meter, voltmeter, ammeter, electrometer
- Independent current and voltage measurement inputs
- Data reading rate up to 5000 readings/second, with time-domain waveform capture
- Charge measurement down to a 2 nC range (1 fC resolution)
- Programmable voltage output: DC, single/double-step scan, list scan, square wave/pulse
- Dedicated temperature and humidity probe input; sorting comparator with up to 7 limits
- SCPI / MODBUS standard; RS232, USB Host/Device, LAN, HANDLER, INTERLOCK interfaces
8 models, one platform
| Model | Functions | Current resolution | Lowest current range | Max. resistance | Voltage source | Voltage measurement | Charge | Quote |
|---|---|---|---|---|---|---|---|---|
| TH2690 | R / V / I / Q | 0.1 fA | 20 pA | 100 PΩ | ±1000 V | 1 µV – 20 V | 1 fC – 2 µC | Quote |
| TH2690A | R / V / I | 1 fA | 2 nA | 1 PΩ | ±1000 V | 1 µV – 20 V | — | Quote |
| TH2690H | R / V / I / Q | 0.01 fA | 2 pA | 1000 PΩ | ±1000 V | 1 µV – 20 V | 1 fC – 2 µC | Quote |
| TH2691 | I | 0.1 fA | 20 pA | — | — | — | — | Quote |
| TH2691A | I | 1 fA | 2 nA | — | — | — | — | Quote |
| TH2691H | I | 0.01 fA | 2 pA | — | — | — | — | Quote |
| TH2695 | R / V / I / Q | 0.01 fA | 2 pA | 3000 PΩ (3 EΩ) | ±3000 V | 30 mV – 3000 V | 1 fC – 2 µC | Quote |
| TH2695A | R / V / I / Q | 0.01 fA | 2 pA | 1500 PΩ | ±1500 V | 15 mV – 1500 V | 1 fC – 2 µC | Quote |
R = high-resistance meter · V = voltmeter · I = ammeter · Q = electrometer (charge). All eight models share the 20 mA top current range and 6½-digit resolution; the lowest current range depends on the model. TH2691 / TH2691A / TH2691H are compact ammeter-only versions without voltage source, voltage input, resistance, charge or temperature/humidity input.
Current measurement ranges
| Range | Accuracy | Resolution | Applicable models |
|---|---|---|---|
| 2 pA | ±(1% + 3 fA) | 0.01 fA | TH2695 / TH2695A / TH2690H / TH2691H |
| 20 pA | ±(0.5% + 3 fA) | 0.1 fA | TH2695 / TH2695A / TH2690 / TH2690H / TH2691 / TH2691H |
| 200 pA | ±(0.5% + 5 fA) | 0.1 fA | TH2695 / TH2695A / TH2690 / TH2690H / TH2691 / TH2691H |
| 2 nA | ±(0.2% + 50 fA) | 1 fA | All models |
| 20 nA | ±(0.2% + 3 pA) | 10 fA | All models |
| 200 nA | ±(0.2% + 5 pA) | 100 fA | All models |
| 2 µA | ±(0.1% + 50 pA) | 1 pA | All models |
| 20 µA | ±(0.05% + 500 pA) | 10 pA | All models |
| 200 µA | ±(0.05% + 5 nA) | 100 pA | All models |
| 2 mA | ±(0.05% + 50 nA) | 1 nA | All models |
| 20 mA | ±(0.05% + 500 nA) | 10 nA | All models |
Applications
Material characterization
Semiconductors, nanomaterials, polymers, dielectric and ferroelectric materials, graphene, ceramics, biological materials, rubber, thin films, metals and organic materials.
Component leakage and insulation
Leakage current and insulation-resistance testing of capacitors, resistors, diodes, transistors, sensors, TFT/CNT devices, opto-electronic and nano-devices, solar cells, switches and relays.
Resistivity and I–V testing
Volume/surface resistivity with the optional TH26090 test fixture; third-generation semiconductor I–V characterization; fast charge testing of capacitive devices.
Industries and application examples
Technical specifications
| Parameter | TH2690 | TH2690A | TH2690H | TH2691 | TH2691A | TH2691H | TH2695 | TH2695A |
|---|---|---|---|---|---|---|---|---|
| Display | 5.0" capacitive touch colour LCD, 6½-digit measurement resolution | |||||||
| Resistance 1 MΩ / 10 MΩ range | ±(0.135% + 1 Ω) / ±(0.135% + 10 Ω) | |||||||
| Resistance 100 MΩ / 1 GΩ range | ±(0.185% + 100 Ω) / ±(0.285% + 1 kΩ) | |||||||
| Resistance 10 GΩ / 100 GΩ range | ±(0.41% + 10 kΩ) / ±(0.41% + 100 kΩ) | |||||||
| Resistance 1 TΩ range | ±(0.45% + 1 MΩ) | |||||||
| Resistance 10 TΩ / 100 TΩ range | ±(0.75% + 10 MΩ) / ±(2.6% + 100 MΩ); not on TH2690A | |||||||
| Resistance measurement models | TH2695, TH2695A, TH2690, TH2690A, TH2690H (not TH2691 / TH2691A / TH2691H) | |||||||
| Max. measurable resistance | TH2695 3000 PΩ (3 EΩ) · TH2695A 1500 PΩ · TH2690H 1000 PΩ · TH2690 100 PΩ · TH2690A 1000 TΩ (1 PΩ) | |||||||
| Voltage measurement, TH2690 / TH2690A / TH2690H | 2 V range ±(0.05% + 40 µV), 1 µV res. · 20 V range ±(0.05% + 400 µV), 10 µV res. · input impedance > 200 TΩ | |||||||
| Voltage measurement, TH2695 | 300 V range ±(0.05% + 600 µV), 100 µV res. · 3000 V range ±(0.05% + 6 mV), 1 mV res. · input impedance 100 MΩ | |||||||
| Voltage measurement, TH2695A | 150 V range ±(0.05% + 300 µV), 100 µV res. · 1500 V range ±(0.05% + 300 µV), 1 mV res. · input impedance 50 MΩ | |||||||
| Charge measurement | 2 nC ±(0.5% + 50 fC), 1 fC res. · 20 nC ±(0.5% + 500 fC) · 200 nC ±(0.5% + 5 pC) · 2 µC ±(0.5% + 50 pC); TH2695 / TH2695A / TH2690 / TH2690H | |||||||
| Voltage source, TH2690 / TH2690A / TH2690H | 20 V ±(0.05% + 2 mV), ±20 mA · 1000 V ±(0.05% + 100 mV), ±1 mA; 1 mV resolution | |||||||
| Voltage source, TH2695 | 40 V ±(0.05% + 4 mV), ±20 mA · 400 V ±(0.05% + 40 mV), ±10 mA · 3000 V ±(0.05% + 300 mV), ±10 mA; 1 mV resolution | |||||||
| Voltage source, TH2695A | 20 V ±(0.05% + 2 mV), ±20 mA · 200 V ±(0.05% + 20 mV), ±10 mA · 1500 V ±(0.05% + 150 mV), ±10 mA; 1 mV resolution | |||||||
| Source functions | DC, scan (single-step, double-step, list scan), ARB (square wave with pulse output, 10 ms min. pulse width, 1 ms resolution) | |||||||
| Temperature probe input | −40 to −10 °C ±1 °C · 10 to 55 °C ±0.5 °C · 55 to 80 °C ±1 °C | |||||||
| Humidity probe input | 0–20% RH ±4% · 20–80% RH ±3% · 80–100% RH ±4% | |||||||
| View modes | Meter, graph (I‑t, V‑t, R‑t, Q‑t, I‑R), histogram, scroll | |||||||
| Input terminals | Current input triaxial BNC; voltage input triaxial BNC (high-voltage BNC on TH2695 / TH2695A); GROUND banana jack | |||||||
| Power supply | AC 90–264 V, 50/60 Hz or DC 127–370 V · 60 W | |||||||
| Operating / storage environment | 0–45 °C, 30–80% RH / −20–60 °C, 10–90% RH (no condensation) | |||||||
| Accuracy-rated environment | 23 °C ± 5 °C, 30–80% RH · warm-up 1 hour · calibration cycle 1 year | |||||||
| Dimensions / weight, TH2690/A/H and TH2691/A/H | Rack mount 215 × 88 × 335 mm · Bench 235 × 111 × 440 mm · 3.5 kg | |||||||
| Dimensions / weight, TH2695A | Rack mount 215 × 88 × 335 mm · Bench 235 × 111 × 440 mm · 4 kg | |||||||
| Dimensions / weight, TH2695 | Rack mount 215 × 88 × 480 mm · Bench 235 × 111 × 590 mm · 5.5 kg | |||||||
Source: TH2690 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- USB Devicestandard
- LANstandard
- HANDLERstandard
- INTERLOCKstandard (not TH2691/A/H)
- SCPI / MODBUSstandard
- Analog / D-A out±2 VFS
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
| TH26017 | USB interface cable |
| TH26058F | φ4 alligator clip (red/black) |
| TH26058D | Connecting cable |
| TH2690_THS | Temperature and humidity probe (not TH2691/A/H) |
More fixtures and adapters are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH2690 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.