Electric vehicles bring high voltages, high currents and new safety requirements into automotive electronics. Battery connections, fuses, chargers, power semiconductors and drive motors all need tests for resistance, insulation and electrical safety, often on many parts at once. The tasks below come from automotive and charging-infrastructure suppliers.
Typical test tasks
| Test task | Component | Typical test conditions | Recommended set-up |
|---|---|---|---|
| Permeability of motor core material | Silicon steel laminations for drive motors | Up to 50 MHz; shielding against the earth’s magnetic field; different sample sizes | TH2851 precision impedance analyzer with TH26088 permeability fixture and permeability software |
| Micro-ohm resistance of fuses | EV fuses | Resistance ≤ 33 µΩ or ≤ 160 µΩ at ≥ 180 °C; several fuses in a temperature chamber | TH8610A tester with TH26060H connecting cable, 4-terminal measurement |
| Hipot and insulation of busbars | Aluminium busbars for 800 V battery systems | ≥ 1 kV on several busbars at once, in a steel-ball test bath | TH9010 parallel hipot tester |
| C-V test of MOSFETs for chargers | MOSFETs in charging stations | Ciss, Coss, Crss; VGS about 20 V, VDS 0–1000 V | TH510 series semiconductor C-V analyzer |
| Safety test of on-board chargers (OBC) | OBC units | AC/DC withstand voltage and insulation resistance on up to 16 test points | TH9110 hipot / insulation tester; for many test points, TH9320-S scanning hipot tester |
| Insulation resistance of relays and contactors | Electromagnetic switches, open state | ≥ 10 GΩ at 100 V DC; values up to 10¹⁵ Ω in development | Development: TH2690H with TH26076B test box. Production: TH2683B |
| Supply simulation for motor tests | Sunroof and other body motors | Start, run and stop under different supply conditions | TH66000 bidirectional DC power system |
| High-current supply for start-stop components | Start-stop system components | Constant current 30 A, CC-to-CV transition, cut-off after 5 s | TH66000 series DC power system |
What to consider
- Many parts per cycle. Parallel multi-channel testers or scanners keep the test time per part low when several busbars, fuses or test points must be tested.
- Contact quality. Open/short detection and contact checks help to avoid false passes caused by poor contact on the fixture.
- Test environment. Tests in temperature chambers or test baths need cables and fixtures rated for the environment and the test voltage.