Industry

Automotive electronics and e-mobility

Resistance, insulation and safety tests for EV fuses, busbars, chargers, relays, power semiconductors and drive motors.

Cable tester mounted above a cable production line with cable reels

Electric vehicles bring high voltages, high currents and new safety requirements into automotive electronics. Battery connections, fuses, chargers, power semiconductors and drive motors all need tests for resistance, insulation and electrical safety, often on many parts at once. The tasks below come from automotive and charging-infrastructure suppliers.

Typical test tasks

Test taskComponentTypical test conditionsRecommended set-up
Permeability of motor core materialSilicon steel laminations for drive motorsUp to 50 MHz; shielding against the earth’s magnetic field; different sample sizesTH2851 precision impedance analyzer with TH26088 permeability fixture and permeability software
Micro-ohm resistance of fusesEV fusesResistance ≤ 33 µΩ or ≤ 160 µΩ at ≥ 180 °C; several fuses in a temperature chamberTH8610A tester with TH26060H connecting cable, 4-terminal measurement
Hipot and insulation of busbarsAluminium busbars for 800 V battery systems≥ 1 kV on several busbars at once, in a steel-ball test bathTH9010 parallel hipot tester
C-V test of MOSFETs for chargersMOSFETs in charging stationsCiss, Coss, Crss; VGS about 20 V, VDS 0–1000 VTH510 series semiconductor C-V analyzer
Safety test of on-board chargers (OBC)OBC unitsAC/DC withstand voltage and insulation resistance on up to 16 test pointsTH9110 hipot / insulation tester; for many test points, TH9320-S scanning hipot tester
Insulation resistance of relays and contactorsElectromagnetic switches, open state≥ 10 GΩ at 100 V DC; values up to 10¹⁵ Ω in developmentDevelopment: TH2690H with TH26076B test box. Production: TH2683B
Supply simulation for motor testsSunroof and other body motorsStart, run and stop under different supply conditionsTH66000 bidirectional DC power system
High-current supply for start-stop componentsStart-stop system componentsConstant current 30 A, CC-to-CV transition, cut-off after 5 sTH66000 series DC power system

What to consider

  • Many parts per cycle. Parallel multi-channel testers or scanners keep the test time per part low when several busbars, fuses or test points must be tested.
  • Contact quality. Open/short detection and contact checks help to avoid false passes caused by poor contact on the fixture.
  • Test environment. Tests in temperature chambers or test baths need cables and fixtures rated for the environment and the test voltage.

Application examples

All applications