TH66000 Series
Bidirectional Regenerative DC Power System, Load and Supply, up to 1500 V / 15 kW
One 3U / 19" hardware platform, three product series. TH66000, TH66000L and TH66000P share the same chassis, the same voltage/current/power ratings and the same 7" capacitive touchscreen user interface; they differ only in which direction they operate. TH66000 is a bidirectional unit that combines a source and a regenerative electronic load in one enclosure; TH66000L is a load-only regenerative electronic load; TH66000P is a source-only programmable DC power supply. Every class from 80 V / 5 kW up to 1500 V / 15 kW is available across all three series, so a project can standardise on one enclosure design and pick the direction it needs per test station.
Technical question about this series? Ask our team.
Key features
- 3U high power density: 5 kW / 10 kW / 15 kW in a single 3U chassis
- Master/slave paralleling, expandable to 480 kW (1 master + up to 15 slaves)
- Energy feedback to the grid up to 93% (TH66000 and TH66000L)
- CV / CC / CR / CP operation
- Built-in function generator: sine, triangle, square, trapezoid, arbitrary waveform; USB LIST import
- List / sequence test with up to 99 steps
- Battery / supercapacitor, PV simulation and MPPT tests (TH66000 and TH66000L)
- 7" 24-bit colour TFT capacitive touchscreen, 800 × 480, English UI
- Real-time voltage/current/power/resistance data logging to USB (CSV), timer function
- Protections: hardware OVP/OCP/OPP, user-configurable alarm events; SCPI and MODBUS standard
17 models, one platform
| Model | Power | Voltage | Current | Int. resistance | Load only (TH66000L) | Source only (TH66000P) | Quote |
|---|---|---|---|---|---|---|---|
| TH6680-120-05 | 5 kW | 0–80 V | 0–120 A | 0.02–25 Ω | TH6680L-120-05 | TH6680P-120-05 | Quote |
| TH6680-240-10 | 10 kW | 0–80 V | 0–240 A | 0.01–13 Ω | TH6680L-240-10 | TH6680P-240-10 | Quote |
| TH6680-360-15 | 15 kW | 0–80 V | 0–360 A | 0.006–10 Ω | TH6680L-360-15 | TH6680P-360-15 | Quote |
| TH66200-70-05 | 5 kW | 0–200 V | 0–70 A | 0.1–150 Ω | TH66200L-70-05 | TH66200P-70-05 | Quote |
| TH66200-140-10 | 10 kW | 0–200 V | 0–140 A | 0.05–75 Ω | TH66200L-140-10 | TH66200P-140-10 | Quote |
| TH66200-210-15 | 15 kW | 0–200 V | 0–210 A | 0.033–50 Ω | TH66200L-210-15 | TH66200P-210-15 | Quote |
| TH66360-40-05 | 5 kW | 0–360 V | 0–40 A | 0.3–520 Ω | TH66360L-40-05 | TH66360P-40-05 | Quote |
| TH66360-80-10 | 10 kW | 0–360 V | 0–80 A | 0.15–260 Ω | TH66360L-80-10 | TH66360P-80-10 | Quote |
| TH66360-120-15 | 15 kW | 0–360 V | 0–120 A | 0.1–180 Ω | TH66360L-120-15 | TH66360P-120-15 | Quote |
| TH66500-30-05 | 5 kW | 0–500 V | 0–30 A | 0.5–1000 Ω | TH66500L-30-05 | TH66500P-30-05 | Quote |
| TH66500-60-10 | 10 kW | 0–500 V | 0–60 A | 0.25–500 Ω | TH66500L-60-10 | TH66500P-60-10 | Quote |
| TH66500-90-15 | 15 kW | 0–500 V | 0–90 A | 0.16–340 Ω | TH66500L-90-15 | TH66500P-90-15 | Quote |
| TH66750-20-05 | 5 kW | 0–750 V | 0–20 A | 1.2–2200 Ω | TH66750L-20-05 | TH66750P-20-05 | Quote |
| TH66750-40-10 | 10 kW | 0–750 V | 0–40 A | 0.6–1100 Ω | TH66750L-40-10 | TH66750P-40-10 | Quote |
| TH66750-60-15 | 15 kW | 0–750 V | 0–60 A | 0.4–740 Ω | TH66750L-60-15 | TH66750P-60-15 | Quote |
| TH661000-40-15 | 15 kW | 0–1000 V | 0–40 A | 0.8–1300 Ω | TH661000L-40-15 | TH661000P-40-15 | Quote |
| TH661500-30-15 | 15 kW | 0–1500 V | 0–30 A | 2.5–3000 Ω | TH661500L-30-15 | TH661500P-30-15 | Quote |
Voltage, current, power and internal-resistance ratings are identical across the three series for a given class; only the source/load direction and the model suffix (plain / "L" / "P") differ. TH66000 = bidirectional (source and regenerative load); TH66000L = load only; TH66000P = source only. The series is continuously expanded; contact Techmize or an authorized distributor for the latest availability.
Function availability by series
| Function | TH66000 (bidirectional) | TH66000L (load) | TH66000P (source) |
|---|---|---|---|
| List / sequence test (up to 99 steps) | ✓ | ✓ | ✓ |
| Built-in function generator | ✓ | ✓ | ✓ |
| Data logging to USB (CSV) + timer | ✓ | ✓ | ✓ |
| Master/slave paralleling (to 480 kW) | ✓ | ✓ | ✓ |
| Battery / supercapacitor test | Charge and discharge | Discharge only | — |
| Simple PV simulation test | ✓ | ✓ | — |
| MPPT tracking test | ✓ | ✓ | — |
| Energy feedback to grid | Up to 93% | Up to 93% | — |
| Wide-range output (auto V/I trade-off) | ✓ | n/a (load) | ✓ |
Applications
R&D and production
R&D and design-verification bench testing, production-line functional test and maintenance, automated test-cell integration, teaching laboratories.
New energy
Solar cells, EV and e-bike power trains, PV panel simulation, LED test. On TH66000P, PV panel simulation means using it as the source half of a test setup with a separate load.
Batteries and supercapacitors
Battery and supercapacitor charge–discharge and capacity test (TH66000), discharge test (TH66000L), supercapacitor charging (TH66000P).
Automotive
Automotive wiring-harness reliability test (TH66000).
Industries and application examples
Technical specifications
| Parameter | TH6680-120-05 | TH6680-240-10 | TH6680-360-15 | TH66200-70-05 | TH66200-140-10 | TH66200-210-15 | TH66360-40-05 | TH66360-80-10 | TH66360-120-15 | TH66500-30-05 | TH66500-60-10 | TH66500-90-15 | TH66750-20-05 | TH66750-40-10 | TH66750-60-15 | TH661000-40-15 | TH661500-30-15 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Voltage resolution (set / readback) | 10 mV | ||||||||||||||||
| Current resolution (set / readback) | 0.1 A (80 V class) · 0.01 A (200 V – 1500 V classes) | ||||||||||||||||
| Power resolution | 1 W | ||||||||||||||||
| Resistance resolution (set) | 0.001 Ω (80 V class) · 0.01 Ω (200 V – 1500 V classes) | ||||||||||||||||
| Resistance resolution (readback) | 0.001 Ω (80 V class) · 0.0001 Ω (200 V – 1500 V classes) | ||||||||||||||||
| Setting accuracy, V / I / P | ≤ 0.1% FS / ≤ 0.2% FS / ≤ 1% FS | ||||||||||||||||
| Setting accuracy, resistance | ≤ 1% of max. resistance value ± 1% of max. current | ||||||||||||||||
| Readback accuracy, voltage | ≤ 0.2% FS (80 V class) · ≤ 0.1% FS (200 V – 1500 V classes) | ||||||||||||||||
| Readback accuracy, I / P | ≤ 0.2% FS / ≤ 1% FS | ||||||||||||||||
| Remote sense compensation | ≤ 0.5% FS (80 V class) · ≤ 5% FS (200 V – 1500 V classes) | ||||||||||||||||
| Dynamic recovery time (50–100% load) | ≤ 1.5 ms | ||||||||||||||||
| Power conversion efficiency (source mode) | Up to 93% | ||||||||||||||||
| Energy feedback efficiency | Up to 93% (TH66000 / TH66000L only) | ||||||||||||||||
| Accuracy conditions | Setting/readback accuracy over 12 months, 25 °C ± 5 °C; % of full scale of the class's rated voltage/current/power | ||||||||||||||||
| Ripple, 80 V / 5 kW | Voltage ≤ 200 mVp-p and 16 mVrms (source mode) · current ≤ 80 mArms | ||||||||||||||||
| Ripple, 80 V / 10 kW | Voltage ≤ 320 mVp-p and 25 mVrms (source mode) · current ≤ 160 mArms | ||||||||||||||||
| Ripple, 80 V / 15 kW | Voltage ≤ 320 mVp-p and 25 mVrms (source mode) · current ≤ 240 mArms | ||||||||||||||||
| Ripple, 200 V / 5 kW | Voltage ≤ 320 mVp-p and 45 mVrms (source mode) · current ≤ 22 mArms | ||||||||||||||||
| Ripple, 200 V / 10 kW | Voltage ≤ 320 mVp-p and 45 mVrms (source mode) · current ≤ 44 mArms | ||||||||||||||||
| Ripple, 200 V / 15 kW | Voltage ≤ 320 mVp-p and 45 mVrms (source mode) · current ≤ 66 mArms | ||||||||||||||||
| Ripple, 360 V / 5 kW | Voltage ≤ 320 mVp-p and 55 mVrms (source mode) · current ≤ 18 mArms | ||||||||||||||||
| Ripple, 360 V / 10 kW | Voltage ≤ 320 mVp-p and 55 mVrms (source mode) · current ≤ 35 mArms | ||||||||||||||||
| Ripple, 360 V / 15 kW | Voltage ≤ 320 mVp-p and 55 mVrms (source mode) · current ≤ 50 mArms | ||||||||||||||||
| Ripple, 500 V / 5 kW | Voltage ≤ 350 mVp-p and 70 mVrms (source mode) · current ≤ 16 mArms | ||||||||||||||||
| Ripple, 500 V / 10 kW | Voltage ≤ 350 mVp-p and 70 mVrms (source mode) · current ≤ 32 mArms | ||||||||||||||||
| Ripple, 500 V / 15 kW | Voltage ≤ 350 mVp-p and 70 mVrms (source mode) · current ≤ 48 mArms | ||||||||||||||||
| Ripple, 750 V / 5 kW | Voltage ≤ 800 mVp-p and 200 mVrms (source mode) · current ≤ 16 mArms | ||||||||||||||||
| Ripple, 750 V / 10 kW | Voltage ≤ 800 mVp-p and 200 mVrms (source mode) · current ≤ 32 mArms | ||||||||||||||||
| Ripple, 750 V / 15 kW | Voltage ≤ 800 mVp-p and 200 mVrms (source mode) · current ≤ 48 mArms | ||||||||||||||||
| Ripple, 1000 V / 15 kW | Voltage ≤ 1600 mVp-p and 300 mVrms (source mode) · current ≤ 16 mArms | ||||||||||||||||
| Ripple, 1500 V / 15 kW | Voltage ≤ 2400 mVp-p and 400 mVrms (source mode) · current ≤ 26 mArms | ||||||||||||||||
| AC mains input | 342–528 VAC, 44–66 Hz, three-phase (all classes and series) | ||||||||||||||||
| Display | 7" 24-bit colour TFT capacitive touchscreen, 800 × 480, English UI | ||||||||||||||||
| Chassis dimensions (W × H × D) | Enclosure 430 × 133 × 703.5 mm; full 3U/19" rack unit 483 × 133 × 793.5 mm | ||||||||||||||||
| Weight | 22 kg (5 kW) / 31 kg (10 kW) / 38 kg (15 kW) | ||||||||||||||||
Voltage ripple applies to TH66000 and TH66000P in source mode; TH66000L has no source mode.
Source: TH66000 Series Family Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- GPIBstandard
- LANstandard
- USB Hoststandard
- USB Devicestandard
- Analog controlstandard
- SCPI / MODBUSstandard
Downloads
Interested in the TH66000 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.