Hipot & Insulation Resistance Testers

TH9110 Series

AC/DC Withstand Voltage & Insulation Resistance Tester, up to 500 VA

A digitally controlled hipot and insulation-resistance test platform for transformers, motors, windings, passive components and finished electrical products. Closed-loop digital output regulation keeps the test voltage stable regardless of mains fluctuation, while ARC detection, open/short (OSC) contact checking and breakdown-voltage ramp testing improve safety-test reliability and throughput. Five models differ in output power, current range and the availability of high-voltage floating output or CK pin/contact detection.

TH9110TH9110ATH9111TH9111ATH9112A CE

Technical question about this series? Ask our team.

Key features

  • High power output, up to 5 kV / 100 mA / 500 VA AC/DC (TH9110 / TH9110A / TH9112A)
  • Digitally controlled, closed-loop output regulation, unaffected by mains fluctuation
  • 7" 800 × 480 TFT-LCD display, English UI, large-character PASS/FAIL readout
  • High-voltage floating output (TH9110 / TH9111), meeting EN 50191 safety requirements
  • Electric-shock protection, selectable on all five models
  • ARC detection for early insulation-degradation and arc-discharge detection
  • Contact check (OSC) flags open or shorted test leads before they cause false results
  • CK pin/contact detection (TH9112A) confirms DUT connection before the HV test
  • Breakdown-voltage ramp test mode for dielectric-strength analysis
  • One-key screen capture; rear-panel HV output; 100 files, up to 50 steps per file

5 models, one platform

ModelAC powerFloating outputLeakageWeightQuote
TH9110High power, floating output 500 VAYes< 3.5 mA21 kg Quote
TH9110AHigh power, standard output 500 VA——21 kg Quote
TH9111Compact power, floating output 200 VAYes< 3.5 mA20 kg Quote
TH9111ACompact power, standard output 200 VA——20 kg Quote
TH9112AHigh current, CK pin detection 500 VA——21 kg Quote

TH9110/TH9110A/TH9111/TH9111A cover 0.05–5.00 kV AC / 0.05–6.00 kV DC withstand voltage and 0.05–5.00 kV insulation resistance (0.1 MΩ – 50.0 GΩ); TH9110/TH9111 add high-voltage floating output. TH9112A is the high-current variant: same voltage ranges, 500 VA output in AC and DC modes, insulation resistance to 100 GΩ, and CK pin/contact detection instead of floating output.

Applications

Windings and high-power products

Transformers, generators/motors and other winding products, such as motor stators and rotors with high parasitic capacitance, requiring high-power withstand-voltage testing.

Components and electrical products

Capacitors, coils, cores, choke coils and filters; household appliances, information and audio-visual products, electric heating appliances and lighting equipment; wire, non-woven fabric and insulation materials.

Automated and specialised testing

Production-line automation via rear-panel HV output; automated test systems; new-energy vehicle components; medical equipment.

Industries and application examples

Technical specifications

ParameterTH9110TH9110ATH9111TH9111ATH9112A
AC output voltage 0.05 – 5.00 kV, 50/60 Hz ±0.1% sine wave
Output power 500 VA500 VA200 VA200 VA500 VA
DC output voltage 0.05 – 6.00 kV
DC output ripple ————−2% / +3% of avg. (5 kV / 100 mA resistive load)
Load variance ±(1% setting + 0.2% F.S.), at rated power
Voltage resolution / accuracy 2 V / ±(1% setting + 0.1% F.S.)
AC current range 0.001–120 mA (≤ 4 kV), 0.001–100 mA (> 4 kV)0.001–120 mA (≤ 4 kV), 0.001–100 mA (> 4 kV)0.001–40 mA0.001–40 mA0.001–120 mA (≤ 4 kV), 0.001–100 mA (> 4 kV)
AC current resolution / accuracy 1 µA / ±(1% reading + 0.5% F.S.)
DC current range 0.0001–25 mA (≥ 1.5 kV), 0.0001–20 mA (< 1.5 kV)0.0001–25 mA (≥ 1.5 kV), 0.0001–20 mA (< 1.5 kV)0.0001–20 mA (< 1.5 kV)0.0001–20 mA (< 1.5 kV)0.0001–100 mA (≤ 5 kV), 0.0001–90 mA (5–5.5 kV), 0.0001–80 mA (> 5.5 kV)
DC current resolution / accuracy 0.1 µA / ±(1% reading + 0.5% F.S.)
Max. short-circuit current 200 mA (AC test only)200 mA (AC test only)80 mA (AC test only)80 mA (AC test only)200 mA
IR output voltage DC 0.05–5.00 kV, 2 V res., ±(1% reading + 0.1% F.S.)DC 0.05–5.00 kV, 2 V res., ±(1% reading + 0.1% F.S.)DC 0.05–5.00 kV, 2 V res., ±(1% reading + 0.1% F.S.)DC 0.05–5.00 kV, 2 V res., ±(1% reading + 0.1% F.S.)DC 0.05–6.00 kV, 2 V res., ±(1% reading + 0.1% F.S.)
IR resistance range 0.1 MΩ – 50.0 GΩ0.1 MΩ – 50.0 GΩ0.1 MΩ – 50.0 GΩ0.1 MΩ – 50.0 GΩ0.1 MΩ – 100.0 GΩ
IR accuracy ≥ 1 kV 1–1000 MΩ: ±(3% rdg + 0.1% F.S.); 1–10 GΩ: ±(7% rdg + 2% F.S.); 10–50 GΩ: ±(10% rdg + 1% F.S.)1–1000 MΩ: ±(3% rdg + 0.1% F.S.); 1–10 GΩ: ±(7% rdg + 2% F.S.); 10–50 GΩ: ±(10% rdg + 1% F.S.)1–1000 MΩ: ±(3% rdg + 0.1% F.S.); 1–10 GΩ: ±(7% rdg + 2% F.S.); 10–50 GΩ: ±(10% rdg + 1% F.S.)1–1000 MΩ: ±(3% rdg + 0.1% F.S.); 1–10 GΩ: ±(7% rdg + 2% F.S.); 10–50 GΩ: ±(10% rdg + 1% F.S.)1–1000 MΩ: ±(3% rdg + 1 MΩ); 1–10 GΩ: ±(7% rdg + 0.2 GΩ); 10–100 GΩ: ±(10% rdg + 0.5 GΩ)
IR accuracy < 500 V 0.1–1000 MΩ: ±(5% rdg + 2% F.S.)0.1–1000 MΩ: ±(5% rdg + 2% F.S.)0.1–1000 MΩ: ±(5% rdg + 2% F.S.)0.1–1000 MΩ: ±(5% rdg + 2% F.S.)0.1–1000 MΩ: ±(5% rdg + 100 V/Vs × 10 MΩ)
ARC detection level AC 1.0 – 20.0 mA / DC 1.0 – 10.0 mA
OSC sample capacitance / thresholds 0.001 – 40 nF; open 10%–100%, short 100%–500% (test signal 600 Hz, 1 s)
CK pin/contact detection ————Test voltage 0.1–0.5 kV, current lower limit 0.001–5 mA
Breakdown-voltage test AC / DC; start 0.05 kV to end 5 kV; step mode (2–999 steps) or voltage-step mode (5–500 V); 0.3–999 s per step
Test time 0.3 – 999 s (0 = continuous)
Rise / fall time 0.1 – 999.9 s (0 = off)
Waiting time (DC / IR) 0.1 – 999 s (0 = off)
Time accuracy ±(1% + 0.1 s)
High-voltage floating output ACW/DCW/IR, leakage < 3.5 mA—ACW/DCW/IR, leakage < 3.5 mA——
Electric-shock protection 0.5 mA ±0.25 mA, selectable on/off
Interlock / panel protection Interlock pin must be pulled low to enable HV output; key lock, password
Internal storage 100 files, up to 50 steps per file
Operating / storage temperature 0–45 °C, 20–90% RH / −10–55 °C, < 80% RH
Power supply / consumption 100 – 240 V AC, 47 – 63 Hz; idle < 100 W, rated 1000 W
Dimensions (W × H × D) 430 × 132 × 500 mm
Weight 21 kg21 kg20 kg20 kg21 kg

Source: TH9110 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard
  • USB Devicestandard
  • LANstandard
  • Handlerstandard
  • SCPIstandard
  • GPIBoptional

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH90018Withstand-voltage test lead (TH9110 / TH9111 only)
TH90015Withstand-voltage test lead (TH9110A / TH9111A / TH9112A only)
TH90003R / BWithstand-voltage test lead (TH9112A only)

Optional test fixtures

ItemDescription
TH90015Test cable
TH90003R / BTest cable with clips

More accessories are available on request from Techmize or your authorized distributor.

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH9110 Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote