Hipot & Insulation Resistance Testers

TH9120 Series

AC/DC Hipot & Insulation Resistance Tester, AC 10 kV / DC 12 kV

A high-power AC/DC withstand-voltage and insulation-resistance test platform for components and devices with high insulation ratings: high-voltage optocouplers, relays, switches, PV modules, motors and non-electrical insulating materials. AC output reaches 10 kV / 20 mA / 200 VA, DC output reaches 12 kV / 10 mA / 120 VA, with a dedicated breakdown-voltage test mode for characterising the true insulation limit of a device.

TH9120TH9120ATH9120D CE

Technical question about this series? Ask our team.

Key features

  • AC withstand voltage: 10 kV / 20 mA / 200 VA output
  • DC withstand voltage: 12 kV / 10 mA / 120 VA output
  • Breakdown-voltage test: AC 0.05–10.0 kV / DC 0.05–12.0 kV, 10 V resolution
  • Insulation resistance test: 0.1 MΩ – 50.0 GΩ
  • ARC (electrical-discharge) detection function
  • Open/short-circuit detection (OSC) on TH9120 and TH9120A
  • 7" 800 × 480 TFT-LCD display with list-mode multi-step view
  • One-click screenshot; contact check (lead continuity)
  • Rear-panel HV output for automated production-line integration
  • Storage: 100 files, up to 50 steps per file

3 models, one platform

TH9120

All-in-one: AC/DC withstand voltage, IR, OSC

Test modes
AC/DC/IR/OSC
AC withstand
10.0 kV / 20 mA
DC withstand
12.0 kV / 10 mA
Insulation R
DC 0.05–12.0 kV
Request a quote for TH9120

TH9120A

Dedicated AC withstand voltage + OSC

Test modes
AC/OSC
AC withstand
10.0 kV / 20 mA
DC withstand
—
Insulation R
—
Request a quote for TH9120A

TH9120D

Dedicated DC withstand voltage + IR

Test modes
DC/IR
AC withstand
—
DC withstand
12.0 kV / 10 mA
Insulation R
DC 0.05–5.0 kV
Request a quote for TH9120D

OSC (open/short-circuit detection) checks the test-lead connection before high voltage is applied, reducing false failures from poor contact; available on TH9120 and TH9120A. All three models share the same 7" display, chassis, standard interfaces and safety functions (shock protection, interlock, key lock/password), and all support SCPI remote control.

Applications

High-insulation devices

High-voltage optocouplers, high-voltage relays, high-voltage switches and other components requiring high withstand-voltage and insulation-resistance testing.

Electronic and electrical products

Capacitors, coils, cores, chokes, filters; household appliances, information and audio-visual products, electric heating appliances, lighting equipment.

Non-electrical and automation

Wire and cable, non-woven fabric and insulating materials; new-energy vehicle components; automated test systems via rear-panel HV output.

Industries and application examples

Technical specifications

ParameterTH9120TH9120ATH9120D
AC voltage range 0.05 – 10.0 kV0.05 – 10.0 kV—
AC waveform 50/60 Hz ±0.1%, sine wave50/60 Hz ±0.1%, sine wave—
AC output power 200 VA (10.0 kV / 20 mA)200 VA (10.0 kV / 20 mA)—
AC current range 0.001 – 20 mA, 0.001 mA resolution0.001 – 20 mA, 0.001 mA resolution—
AC current accuracy 0.100–2.999 mA: ±(1% rdg + 0.5% F.S.); 3.00–20.00 mA: ±(1.5% rdg + 0.5% F.S.)0.100–2.999 mA: ±(1% rdg + 0.5% F.S.); 3.00–20.00 mA: ±(1.5% rdg + 0.5% F.S.)—
Max. short-circuit current 40 mA (AC test only)40 mA (AC test only)—
DC voltage range 0.05 – 12.0 kV—0.05 – 12.0 kV
DC output power 120 VA (12.0 kV / 10 mA)—120 VA (12.0 kV / 10 mA)
DC current range 0.0001 – 10 mA, 0.1 µA resolution (ranges 300 µA / 3 mA / 10 mA)—0.0001 – 10 mA, 0.1 µA resolution (ranges 300 µA / 3 mA / 10 mA)
DC current accuracy ±(1% rdg + 0.5% F.S.)—±(1% rdg + 0.5% F.S.)
Fast discharge Auto-discharge after DCW test—Auto-discharge after DCW test
Load change rate ±(1% set value + 10 V), at rated power
Voltage resolution / accuracy 2 V / ±(1% set value + 0.1% full scale)
IR output voltage DC 0.05 – 12.0 kV—DC 0.05 – 5.0 kV
IR voltage resolution / accuracy 2 V / ±(1% set value + 0.5% F.S.)—2 V / ±(1% set value + 0.5% F.S.)
IR resistance range 0.1 MΩ – 50.0 GΩ—0.1 MΩ – 50.0 GΩ
IR accuracy at ≥ 0.5 kV 1 M–1 GΩ: ±(3% rdg + 0.1% F.S.); 1 G–10 GΩ: ±(7% rdg + 2% F.S.); 10 G–50 GΩ: ±(10% rdg + 1% F.S.)—1 M–1 GΩ: ±(3% rdg + 0.1% F.S.); 1 G–10 GΩ: ±(7% rdg + 2% F.S.); 10 G–50 GΩ: ±(10% rdg + 1% F.S.)
IR accuracy at < 500 V 0.1 M–1 GΩ: ±(5% rdg + 2% F.S.)—0.1 M–1 GΩ: ±(5% rdg + 2% F.S.)
ARC threshold AC 1.0–20.0 mA; DC 1.0–10.0 mAAC 1.0–20.0 mADC 1.0–10.0 mA
OSC sampling capacitance / judgement 0.001–40 nF; open 10%–100%, short 100%–500%0.001–40 nF; open 10%–100%, short 100%–500%—
Test / rise / fall time 0.3–999 s (test); 0.1–999 s (rise, fall); 0 = off / continuous
Shock protection 0.5 mA ±0.25 mA, selectable on/off
Interlock HV output enabled only when the interlock pin is pulled low
Panel protection Key lock, password
Display 7" TFT-LCD, 800 × 480, English UI
Storage 100 files, up to 50 steps per file
Power supply / consumption 100–240 V AC, 47–63 Hz; no-load < 100 W, rated 300 W
Operating / storage environment 0–45 °C, 20–90% RH / −10–55 °C, < 80% RH
Dimensions / weight 430 (W) × 132 (H) × 500 (D) mm, 21 kg

Source: TH9120 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.

Interfaces

  • RS232standard
  • USB Hoststandard
  • USB Devicestandard
  • LANstandard
  • Handlerstandard
  • SCPIstandard
  • GPIBoptional

Accessories

Standard accessories

ItemDescription
—EU power cable (Schuko, CEE 7/7)
TH90015Test cable
TH90003R / BTest cable with clips

Optional test fixtures

ItemDescription
—GPIB interface card

More fixtures and accessories are available on request from Techmize or your authorized distributor.

Photos of fixtures and accessories: click an item code above, or browse all accessories.

Downloads

Interested in the TH9120 Series?

Send us the model, quantity and your application. Our team in Ismaning will answer by email.

Request a quote