Hipot & Insulation Resistance Testers
TH9120 Series
AC/DC Hipot & Insulation Resistance Tester, AC 10 kV / DC 12 kV
A high-power AC/DC withstand-voltage and insulation-resistance test platform for components and devices with high insulation ratings: high-voltage optocouplers, relays, switches, PV modules, motors and non-electrical insulating materials. AC output reaches 10 kV / 20 mA / 200 VA, DC output reaches 12 kV / 10 mA / 120 VA, with a dedicated breakdown-voltage test mode for characterising the true insulation limit of a device.
Technical question about this series? Ask our team.
Key features
- AC withstand voltage: 10 kV / 20 mA / 200 VA output
- DC withstand voltage: 12 kV / 10 mA / 120 VA output
- Breakdown-voltage test: AC 0.05–10.0 kV / DC 0.05–12.0 kV, 10 V resolution
- Insulation resistance test: 0.1 MΩ – 50.0 GΩ
- ARC (electrical-discharge) detection function
- Open/short-circuit detection (OSC) on TH9120 and TH9120A
- 7" 800 × 480 TFT-LCD display with list-mode multi-step view
- One-click screenshot; contact check (lead continuity)
- Rear-panel HV output for automated production-line integration
- Storage: 100 files, up to 50 steps per file
3 models, one platform
TH9120
All-in-one: AC/DC withstand voltage, IR, OSC
- Test modes
- AC/DC/IR/OSC
- AC withstand
- 10.0 kV / 20 mA
- DC withstand
- 12.0 kV / 10 mA
- Insulation R
- DC 0.05–12.0 kV
TH9120A
Dedicated AC withstand voltage + OSC
- Test modes
- AC/OSC
- AC withstand
- 10.0 kV / 20 mA
- DC withstand
- —
- Insulation R
- —
TH9120D
Dedicated DC withstand voltage + IR
- Test modes
- DC/IR
- AC withstand
- —
- DC withstand
- 12.0 kV / 10 mA
- Insulation R
- DC 0.05–5.0 kV
OSC (open/short-circuit detection) checks the test-lead connection before high voltage is applied, reducing false failures from poor contact; available on TH9120 and TH9120A. All three models share the same 7" display, chassis, standard interfaces and safety functions (shock protection, interlock, key lock/password), and all support SCPI remote control.
Applications
High-insulation devices
High-voltage optocouplers, high-voltage relays, high-voltage switches and other components requiring high withstand-voltage and insulation-resistance testing.
Electronic and electrical products
Capacitors, coils, cores, chokes, filters; household appliances, information and audio-visual products, electric heating appliances, lighting equipment.
Non-electrical and automation
Wire and cable, non-woven fabric and insulating materials; new-energy vehicle components; automated test systems via rear-panel HV output.
Industries and application examples
Technical specifications
| Parameter | TH9120 | TH9120A | TH9120D |
|---|---|---|---|
| AC voltage range | 0.05 – 10.0 kV | 0.05 – 10.0 kV | — |
| AC waveform | 50/60 Hz ±0.1%, sine wave | 50/60 Hz ±0.1%, sine wave | — |
| AC output power | 200 VA (10.0 kV / 20 mA) | 200 VA (10.0 kV / 20 mA) | — |
| AC current range | 0.001 – 20 mA, 0.001 mA resolution | 0.001 – 20 mA, 0.001 mA resolution | — |
| AC current accuracy | 0.100–2.999 mA: ±(1% rdg + 0.5% F.S.); 3.00–20.00 mA: ±(1.5% rdg + 0.5% F.S.) | 0.100–2.999 mA: ±(1% rdg + 0.5% F.S.); 3.00–20.00 mA: ±(1.5% rdg + 0.5% F.S.) | — |
| Max. short-circuit current | 40 mA (AC test only) | 40 mA (AC test only) | — |
| DC voltage range | 0.05 – 12.0 kV | — | 0.05 – 12.0 kV |
| DC output power | 120 VA (12.0 kV / 10 mA) | — | 120 VA (12.0 kV / 10 mA) |
| DC current range | 0.0001 – 10 mA, 0.1 µA resolution (ranges 300 µA / 3 mA / 10 mA) | — | 0.0001 – 10 mA, 0.1 µA resolution (ranges 300 µA / 3 mA / 10 mA) |
| DC current accuracy | ±(1% rdg + 0.5% F.S.) | — | ±(1% rdg + 0.5% F.S.) |
| Fast discharge | Auto-discharge after DCW test | — | Auto-discharge after DCW test |
| Load change rate | ±(1% set value + 10 V), at rated power | ||
| Voltage resolution / accuracy | 2 V / ±(1% set value + 0.1% full scale) | ||
| IR output voltage | DC 0.05 – 12.0 kV | — | DC 0.05 – 5.0 kV |
| IR voltage resolution / accuracy | 2 V / ±(1% set value + 0.5% F.S.) | — | 2 V / ±(1% set value + 0.5% F.S.) |
| IR resistance range | 0.1 MΩ – 50.0 GΩ | — | 0.1 MΩ – 50.0 GΩ |
| IR accuracy at ≥ 0.5 kV | 1 M–1 GΩ: ±(3% rdg + 0.1% F.S.); 1 G–10 GΩ: ±(7% rdg + 2% F.S.); 10 G–50 GΩ: ±(10% rdg + 1% F.S.) | — | 1 M–1 GΩ: ±(3% rdg + 0.1% F.S.); 1 G–10 GΩ: ±(7% rdg + 2% F.S.); 10 G–50 GΩ: ±(10% rdg + 1% F.S.) |
| IR accuracy at < 500 V | 0.1 M–1 GΩ: ±(5% rdg + 2% F.S.) | — | 0.1 M–1 GΩ: ±(5% rdg + 2% F.S.) |
| ARC threshold | AC 1.0–20.0 mA; DC 1.0–10.0 mA | AC 1.0–20.0 mA | DC 1.0–10.0 mA |
| OSC sampling capacitance / judgement | 0.001–40 nF; open 10%–100%, short 100%–500% | 0.001–40 nF; open 10%–100%, short 100%–500% | — |
| Test / rise / fall time | 0.3–999 s (test); 0.1–999 s (rise, fall); 0 = off / continuous | ||
| Shock protection | 0.5 mA ±0.25 mA, selectable on/off | ||
| Interlock | HV output enabled only when the interlock pin is pulled low | ||
| Panel protection | Key lock, password | ||
| Display | 7" TFT-LCD, 800 × 480, English UI | ||
| Storage | 100 files, up to 50 steps per file | ||
| Power supply / consumption | 100–240 V AC, 47–63 Hz; no-load < 100 W, rated 300 W | ||
| Operating / storage environment | 0–45 °C, 20–90% RH / −10–55 °C, < 80% RH | ||
| Dimensions / weight | 430 (W) × 132 (H) × 500 (D) mm, 21 kg | ||
Source: TH9120 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- USB Devicestandard
- LANstandard
- Handlerstandard
- SCPIstandard
- GPIBoptional
Accessories
Standard accessories
| Item | Description |
|---|---|
| — | EU power cable (Schuko, CEE 7/7) |
| TH90015 | Test cable |
| TH90003R / B | Test cable with clips |
Optional test fixtures
| Item | Description |
|---|---|
| — | GPIB interface card |
More fixtures and accessories are available on request from Techmize or your authorized distributor.
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH9120 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.