Hipot & Insulation Resistance Testers
TH9130 Series
Multifunction Safety Compliance Analyzer, 7-in-1
A single-channel, seven-in-one electrical safety test system combining AC/DC withstand voltage, insulation resistance, ground bond, continuity, electrical performance and leakage current testing in one 7-inch touchscreen instrument (TH9130A/TH9131A do not include the electrical performance and leakage current tests). Suited to safety-compliance testing of household appliances, lighting, motors, high-power equipment, electronic components and medical electrical equipment.
Technical question about this series? Ask our team.
Key features
- 7-inch capacitive touchscreen, 800 × 480, English UI
- Seven-in-one: ACW, DCW, insulation resistance, ground bond, continuity, electrical performance and leakage current (TH9130/TH9131)
- 500 VA AC withstand-voltage output; insulation resistance test up to 6 kV / 50 GΩ
- Ground bond test up to 40 A; can run simultaneously with withstand voltage to shorten test time
- Open/short-circuit detection (OSC) and arc detection (ARC)
- Electrical performance test up to 277 V / 16 A / 4500 W (TH9130/TH9131)
- Leakage current test with selectable body-impedance networks MD A–H (TH9130/TH9131)
- Single-screen step view plus list mode with all step results and pass/fail
- Shock-protection cut-off, lockable panel, pass/fail alarm
- Standard SCPI; storage for 100 files, 50 steps per file
4 models, one platform
TH9130
- AC withstand
- 5.0 kV / 100 mA / 500 VA
- DC withstand
- 6.0 kV / 20 mA / 150 VA
- Electrical performance
- Included
- Leakage current
- Included
- Weight
- 40 kg
TH9131
- AC withstand
- 5.0 kV / 40 mA / 200 VA
- DC withstand
- 6.0 kV / 20 mA / 120 VA
- Electrical performance
- Included
- Leakage current
- Included
- Weight
- 38 kg
TH9130A
- AC withstand
- 5.0 kV / 100 mA / 500 VA
- DC withstand
- 6.0 kV / 20 mA / 150 VA
- Electrical performance
- Not available
- Leakage current
- Not available
- Weight
- 34 kg
TH9131A
- AC withstand
- 5.0 kV / 40 mA / 200 VA
- DC withstand
- 6.0 kV / 20 mA / 120 VA
- Electrical performance
- Not available
- Leakage current
- Not available
- Weight
- 32 kg
All four models share the same touchscreen platform, interfaces (RS232 / USB / LAN / Handler, optional GPIB) and SCPI support. TH9130A/TH9131A cover ACW, DCW, insulation resistance, ground bond and continuity; they do not include the electrical performance or leakage current test functions.
Applications
Household appliances and lighting
Full electrical safety and performance testing of household appliances; comprehensive lighting-appliance safety testing.
Motors and high-power equipment
Comprehensive electric-motor safety testing; withstand-voltage and ground-bond testing of high-power appliances.
Components and medical equipment
Comprehensive component safety testing; leakage current testing per IEC 60601 (TH9130/TH9131).
Industries and application examples
Technical specifications
| Parameter | TH9130 | TH9131 | TH9130A | TH9131A |
|---|---|---|---|---|
| AC voltage range | 0.05 – 5.0 kV, 50/60 Hz ±0.1% sine wave | |||
| AC output power | 500 VA (5.0 kV / 100 mA) | 200 VA | 500 VA | 200 VA |
| DC voltage range | 0.05 – 6.0 kV | |||
| DC output power | 150 VA (6.0 kV / 20 mA) | 120 VA | 150 VA | 120 VA |
| Voltage accuracy | ±(1% set value + 5 V); resolution 2 V | |||
| AC current range | 0.001 – 120 mA (V ≤ 4 kV) / 100 mA (V > 4 kV) | 0.001 – 40 mA | 0.001 – 120 mA (V ≤ 4 kV) / 100 mA (V > 4 kV) | 0.001 – 40 mA |
| DC current range | 0.0001 – 20 mA | |||
| Test / rise / fall / wait time | 0.3–999 s / 0.1–999 s / 0.1–999 s / 0.1–999 s (0 = continuous / off) | |||
| Arc detection (AC / DC) | 1.0–20.0 mA / 1.0–10.0 mA | 1.0–20.0 mA / — | 1.0–20.0 mA / 1.0–10.0 mA | 1.0–20.0 mA / — |
| Max. short-circuit current (AC) | 200 mA | 80 mA | 200 mA | 80 mA |
| IR output voltage | DC 0.05 – 6.0 kV, resolution 2 V, accuracy ±(1% reading + 5 V) | |||
| IR resistance range | 0.05 MΩ – 50.0 GΩ | |||
| IR accuracy (V ≥ 500 V) | 1 MΩ–1 GΩ: ±(3% reading + 1 MΩ); 1–10 GΩ: ±(7% reading + 0.2 GΩ); 10–50 GΩ: ±(10% reading + 0.5 GΩ) | |||
| IR accuracy (V < 500 V) | 1 MΩ – 1 GΩ: ±(5% reading + 100 V/Vs × 10 MΩ) | |||
| Ground bond output current | 1.00 – 40.00 A, ±(2% set value + 2 digits) | |||
| Ground bond test voltage | 3.00 – 8.00 V, 50/60 Hz ±0.1% | |||
| Ground bond resistance range | 0–600 mΩ (1–10 A), 0–200 mΩ (10–30 A), 0–150 mΩ (30–40 A); accuracy ±(2–3% reading + 2–3 digits) | |||
| Synchronous ACW + GB test | 5 kVac/50 mAac & 30 Aac/150 mΩ | 5 kVac/30 mAac & 30 Aac/150 mΩ | 5 kVac/50 mAac & 30 Aac/150 mΩ | 5 kVac/30 mAac & 30 Aac/150 mΩ |
| Continuity | 0.0001–0.1 A / 0.00–10,000 Ω; accuracy ±(1% reading + 3–10 digits) | |||
| Electrical performance (V / I / P) | 0–277.0 V / 0–16.00 A / 0–4500 W | 0–277.0 V / 0–16.00 A / 0–4500 W | Not available | Not available |
| Power factor / leakage (performance test) | 0.000–1.000 / 0.00–10.00 mA | 0.000–1.000 / 0.00–10.00 mA | — | — |
| Leakage current test | 0–277 Vac, 16 Aac max; 0.0 µA – 10.00 mA; DC, 15 Hz – 1 MHz | 0–277 Vac, 16 Aac max; 0.0 µA – 10.00 mA; DC, 15 Hz – 1 MHz | Not available | Not available |
| Body-impedance networks (MD) | A–H, each for a product-safety standard (see datasheet) | A–H, each for a product-safety standard (see datasheet) | — | — |
| OSC detection | 0.001–40 nF; open 10–100%, short 100–500% | |||
| Shock protection | 0.5 mA ±0.25 mA, selectable on/off; interlock pin must be pulled low to enable HV output | |||
| Alarm / lock | Pass: short tone + green light. Fail: long tone + red light. Lock-on-fail, panel key-lock | |||
| Storage | 100 files, 50 steps per file | |||
| Operating / storage environment | 0–45 °C, 20–90% RH / −10–55 °C, < 80% RH | |||
| Power supply / power | 100–240 V AC, 47–63 Hz; no-load < 100 W, rated 1200 W | |||
| Dimensions (W × H × D) | 430 × 132 × 550 mm | |||
| Weight | 40 kg | 38 kg | 34 kg | 32 kg |
Source: TH9130 Series Datasheet, Rev. 2026-09. Specifications subject to change without notice.
Interfaces
- RS232standard
- USB Hoststandard
- USB Devicestandard
- LANstandard
- Handlerstandard
- SCPIstandard
- GPIBoptional
Accessories
Photos of fixtures and accessories: click an item code above, or browse all accessories.
Downloads
Interested in the TH9130 Series?
Send us the model, quantity and your application. Our team in Ismaning will answer by email.