Manufacturers of capacitors, inductors and transformers test every part for its electrical parameters and its insulation, often at line speed. Tonghui instruments are used in R&D labs and in automated production lines for these components, from single test stations to complete multi-station lines.
Typical test tasks
| Test task | What is measured | Recommended instruments | More |
|---|---|---|---|
| Transformer production test | Transformer parameters such as inductance and DC resistance across many pins | TH2840X automatic transformer test system with scanning fixtures | Photos below |
| Inter-turn insulation of windings | Shorted turns and layer-to-layer faults, by impulse waveform comparison | TH2883 impulse winding tester | Inductor DC bias and inter-turn test |
| Hipot test in component production | Withstand voltage and leakage current, several parts in parallel | TH9010 parallel hipot tester, TH9320-S scanning hipot tester | SMD capacitor hipot |
| Inductor DC bias (saturation) | Inductance and Q versus DC current | LCR meter with TH1779A DC bias current source | Inductor DC bias and inter-turn test |
| Capacitor capacitance and loss | Capacitance and dissipation factor (D) at production speed | LCR meters such as TH2840 or TH283X, integrated in the line | — |
| Insulation resistance | Insulation resistance of components and materials | TH2683 insulation resistance meter | — |
| Ferrite cores and EMC components | Impedance magnitude and phase over frequency | TH2851 precision impedance analyzer | EMC filter components |
Test stations or complete lines
On the production lines in the photos below, several test steps run in sequence on one line: for example transformer parameter test, impulse winding test and hipot test, each at its own station. The instruments communicate with the line control through handler and communication interfaces. Send us your test plan and line layout, and we will check which instruments and interfaces fit.